Harlequin Sewage Pump Station For Sale at EasyMerchant
Our range of Harlequin sewage pumping stations are made of ​​a hardwearing polyethylene material and include a pipework system, DAB pump, and MDPE type body. They are available with effluent, sewage, or grinder pumps (depending on the type of waste), in capacities ranging from 450 to 1100 litres, and in single or twin options. Like all of our products, these sewage pumping stations meet British manufacturing standards, and are available for the best price in the UK.
The sewage pump stations we stock can be used in a variety of applications, ranging from domestic waste disposal to commercial use, and are all easy to implement. If you have any questions regarding the type of sewage pump station you require or how to install or maintain a pump station you have purchased from us, get in touch with our customer service team and we can help.
The Harlequin Sewage Pumping Station can provide 24 hour pump and storage capabilities, and different varieties can be used for pumping sewage for both domestic and commercial sewage treatment use.
What Does The Harlequin Sewage Pumping Station Include?
The Harlequin sewage pumping station features a straightforward pipework system, high quality DAB pump, and an easy to implement MDPE type body.
All pumping station varieties are made of a durable polyethylene material of medium density, and have pump options for effluent, sewage, or waste water.
What Sizes of Sewage Pumping Station Are Available?
The Harlequin pumping stations are available in 450, 800, and 1100 litre sizes.
Additionally, a variety of types of packaged sewage pumping station are available for a range of domestic and commercial needs, including:
- Single effluent stations typically used for pumping treated effluent to a watercourse or field drainage
- Twin pump effluent stations that can pump more liquid for sites with ground unsuitable for soakaways, or for larger sewage treatment plants to pump treated effluent into a watercourse of field drainage. Not usually required for septic tanks.
- Single sewage pump stations designed for solid and liquid waste, usually used for a single dwelling or extension in which waste is pumped to a private manhole cover
- Twin sewage stations for large or multiple dwellings to pumping sewage to the main sewer
- Single grinder stations for heavy solids and liquid waste, designed to reduce the number of litres per second at which sewage enters a main sewer
- Twin grinder stations can handle a large amount of heavy solids and liquid waste, and are used in places like campsites where guests may flush products not meant for a main sewer – grinder pumps are less likely than vertex pumps to block
Shop for Sewage Pumping Stations At EasyMerchant
Easy Merchant has the lowest prices on the web for plumbing supplies, so you know you’re getting the best deal on a packaged pump station.
As all our products meet or exceed British manufacturing standards, you can be sure that you’ll be getting a high quality pump station.
Harlequin Pumping Station is capable of providing 24-hour pump & storage capabilities for domestic applications. Harlequin Pump Stations can be specified for water / effluent including post wastewater and sewage treatment systems, sewage directly from the home and applications requiring a grinder pump.
Features include a durable and easy to install MDPE tank body, simple and effective pipework system and market leading DAB pump.
Single Effluent pump stations comprise of a single pump, designed for liquid effluent only – often used after a domestic sewage treatment plant to pump treated effluent to a watercourse of field drainage.
Single Sewage
Single Sewage pump stations comprise of a single vortex pump, designed for solid and liquid waste – most commonly used on a single dwelling or an extension to pump sewage to a private manhole cover.
Single Grinder
Single Grinder pump stations comprise of a single pump, designed for heavy solids and liquid waste – often used to reduce the amount of litres per second entering a mains sewer as the water authorities in certain areas are very strict about the amount the sewage system can cope with.
Twin Effluent pump stations comprise of two pumps and a control panel. Twin pumps can cope with much bigger amounts of liquid – often used for service water on sites where ground conditions aren’t suitable for soakaways, or for larger commercial treatment plant to pump the treated effluent to a watercourse or field drainage.
Twin Sewage
Twin Sewage pump stations comprise of two vortex pumps designed to cope with solid and liquid waste. They also include a control panel. twin pumps are most commonly used on larger domestic dwelling or multiple dwellings that are discharging to the main sewer.
Twin Grinder
Twin Grinder pump stations comprise of two pumps and a control panel. Grinder pumps can cope with bigger amounts of solid matter and liquid waste – often used in a commercial setting like a campsite where guests tend to flush products that aren’t designed to enter the mains sewer – Grinder pumps are less likely to block and can handle bigger rogue items better than vortex pumps.
Harlequin 450 Litre Pump Station:
- Moulded from durable medium density polyethylene material
- 110mm inlet connection
- 50mm or 63mm outlet connection (depending on pump type)*
- 110mm services duct
- Integrated lifting eyes for ease of handling and installation
- Double sealed 600x600mm galvanised steel manhole cover, c/w locking screws
- Brass gate valve and PVC Union connection for ease of servicing
- Stainless steel pump lifting chain
- Pump options available for water, effluent and sewage
- Non-return valve on all pumps
Harlequin 800 Litre Pump Station:
- Moulded from durable medium density polyethylene material
- 110mm inlet connection
- 50mm or 63mm outlet connection (depending on pump type)*
- 110mm services duct
- Integrated lifting eyes for ease of handling and installation
- Double sealed 600x600mm galvanised steel manhole cover, c/w locking screws
- Brass gate valve and PVC Union connection for ease of servicing
- Stainless steel pump lifting chain(s)
- Pump options available for water, effluent and sewage
- Single and twin pump configurations
- Non-return valve on all pumps
- Control panel and float switches (twin pump configurations)
- High level alarm (twin pump configurations)
- Guide rails (grinder pumps)
Harlequin 1100 Litre Pump Station:
- Moulded from durable medium density polyethylene material
- 110mm inlet connection
- 50mm or 63mm outlet connection (depending on pump type)*
- 110mm services duct
- Integrated lifting eyes for ease of handling and installation
- Double sealed 600x600mm galvanised steel manhole cover, c/w locking screws
- Brass gate valve and PVC Union connection for ease of servicing
- Stainless steel pump lifting chain(s)
- Pump options available for water, effluent and sewage
- Single and twin pump configurations
- Non-return valve on all pumps
- Control panel and float switches (twin pump configurations)
- High level alarm (twin pump configurations)
- Guide rails (grinder pumps)
Adam –